6.5Calibration
Beforerstusecalibrationproceduresmustbecarriedoutto
ensureoptimumperformanceoftheinstrumentwiththevessel.
Thecalibrationproceduresare:
Usercalibration
Intermediatecalibration
Groupsetup
Dealercalibration
Note:Groupsetupisforgroupilluminationandisnotpartof
thecalibrationprocess.
Usercalibration
Thei60Closehauledwindisarepeatdisplayandassuchdoes
notrequirecalibration,thestepsbelowapplytothecalibrationof
thei60Windinstrumentonly.
Usercalibrationoptionsinclude:
Windangleoffset
Windspeedunits
Linearizingandaligningthewindtransducer
Youcanlinearizeandalignthewindtransducerbyfollowing
thestepsbelow.
Youwillneedtobeunderway,withsufcientspacetoturnina
largecircleunhindered.
1.Slowlyturnthevesselthrough2completecircles.
x 2
D12 41 5-1
Thisprocedureautomaticallylinearizesthewindvane.A
successfullinearizationisindicatedbythedigitaldisplay
ashingandabuzzersoundingthreebeeps.
2.PressandholdthePowerandTrue/Appbutton
simultaneouslyforapproximately2secondstoentertheuser
calibrationmenu.
True
App
+
D12 48 8-1
10
15
20
25
30
35
40
45
50
55
60
5
2
3.PressthePowerbuttontodisplaythewindangleoffsetpage.
D12 48 9-1
4.Sailyourvesseldirectlyintothewindandadjusttheanalog
pointerto0,usingtheVMGandTackbuttons.
D12 49 0-1
Ta ck
VMG
TheVMGbuttonwilldecreasethecurrentvalueandthe
Tackbuttonwillincreasethecurrentvalue.Asyoudothis,
thewindangleoffsetshowstheamountofcorrectionyou
haveapplied.
5.Toexittheusercalibrationpagesatanytimepressand
holdthePowerandTrue/Appbuttonssimultaneouslyfor
approximately2seconds.
Selectingwindspeedunits
Windspeedunitscanbedisplayedineitherknotsormetersper
second.Tochangethewindspeedunitsfollowthestepsbelow.
Fromtheusercalibrationpages:
1.PressthePowerbuttontodisplaythewindspeedunits
page,or
D12 49 1-1
2.UsetheVMGandTackbuttonstoselecttherequiredwind
units.
3.Toexittheusercalibrationpagesatanytimepressand
holdthePowerandTrue/Appbuttonssimultaneouslyfor
approximately2seconds.
Intermediatecalibration
Intermediatecalibrationallowsyouto:
i60Windi60Closehauledwind
Checkinstrumentsoftwareversion.Checkinstrumentsoftwareversion.
Checktheinstrumentstatus(either
masterorrepeater).
10
15
20
25
30
35
40
45
50
55
60
5
4
+
D12 49 2-1
CAL
True
App
Checkingthesoftwareversion
Youcancheckthesoftwareversionoftheunitbyfollowingthe
stepsbelow.
Duringnormaloperation:
1.PressandholdthePowerandTrue/Appbuttons
simultaneouslyforapproximately4seconds.
Thecurrentsoftwareversionisdisplayed.Thesoftware
versionpagewilltime-outautomaticallyafter8secondsof
inactivity.
2.PressthePowerbuttontodisplaytheinstrumentstatus.
Checkingtheinstrumentstatus
Youcanchecktheinstrumentdisplay'sstatusbyfollowingthe
stepsbelow.
Fromthesoftwareversionpage:
1.PressthePowerbutton.
Theinstrumentstatusisdisplayed(r0=masterandr1
=repeater).Theinstrumentstatuspagewilltime-out
automaticallyafter8secondsofinactivity.
Dealercalibration
Thedealercalibrationproceduresinclude:
SettingUsercalibrationoptionsonoroff.
Settingrequiredwindangleandspeedresponse.
Settingthevelocitymadegood(VMG)response.
Settingboatshowmodeonoroff.
Restorefactorydefault
Settingdealercalibrationoptions
Tosetthedealercalibrationoptionsfollowthestepsbelow:
Duringnormaloperation:
1.PressandholdthePowerandTrue/Appbuttonsfor
approximately14secondstodisplaythedealercalentry
page.
10
15
20
25
30
35
40
45
50
55
60
5
14
+
D12 49 3-1
True
App
CAL
2.PresstheVMGandTackbuttonssimultaneouslytodisplay
theusercalibrationaccesspage.
+
D12 49 4-1
Ta ck
VMG
CAL
CAL
32i60