Note:
Thesuitablefuseratingforthethermalbreak
erisdependenton:1)Howmanydevicesyouhave
connectedtoyourSea Talkng®network;and2)Howmanydevicesaresharingthesamethermal
breakerthatyourSeaTalkng®networkisconnectedto.
Sea
Talkng®systemloading
Themaximumloading/LENforaSea Talkng®systemdependsonthelengthofthebackbone.
Unbalancedsystemloading:
BackboneL ength:0m(0ft)to20m(66ft)MaximumLEN:40
BackboneLength:>20m(66ft)to40m(131ft)MaximumLEN:20
BackboneLength:>40m(131ft)to60m(197ft)MaximumLEN:14
Balancedsystemloading:
BackboneL ength:0m(0ft)to60m(197ft)MaximumLEN:100
BackboneLength:>60m(197ft)to80m(262ft)MaximumLEN:84
BackboneLength:>80m(262ft)to100m(328ft)MaximumLEN:60
BackboneLength:>100m(328ft)to120m(394ft)MaximumLEN:50
BackboneLength:>120m(394ft)to160m(525ft)MaximumLEN:40
BackboneLength:>160m(525ft)to200m(656ft)MaximumLEN:32
PowerdistributionSeaTalkng®
Recommendationsandbestpractice.
OnlyuseapprovedSea Talkng®powercables.DoNOTuseapowercabledesignedfor,or
suppliedwith,adifferentproduct.
Seebelowformoreinformationonimplementationforsomecommonpowerdistributionscenarios.
Important:
Whenplanningandwiring,tak eintoconsiderationotherproductsinyoursystem,someofwhich
(e.g.sonarmodules)mayplacelargepowerdemandpeaksonthevessel’selectricalsystem,
whichmayimpactthevoltageavailabletootherproductsduringthepeaks.
Theinformationprovidedbelowisforguidanceonly,tohelpprotectyourproduct.Itcovers
commonvesselpowerarrangements,butdoesNOTcovereveryscenario.Ifyouareunsure
howtoprovidethecorrectlevelofprotection,pleaseconsultanauthorizedRaymarinedealeror
asuitablyqualifiedprofessionalmarineelectrician.
Sea Talkng®powercable(A06049)
WhenpoweringtheSeaTalkng®bus(backboneor5–wayconnector)fromabatteryordistribution
panel,theA06049powercablemustbeused.
All3coresofthecablemustbeconnectedcorrectly:
1.Sea Talkng®spurconnectorconnectstospurconnectionontheSeaTalkng®network.
2.+Red(positive)wireconnectstobatteryordistributionpanelpositiveterminal.
3.Black(negative)wireconnectstobatteryordistributionpanelnegativeterminal.
4.GroundwireconnectstoRFgroundpoint,ifnogroundpointisavailableconnecttothebattery
negative(-)terminal.
Connections35