4.Select Y
es.
Y ourunitwillnowresetitselftofactorydefaultsettings.
6.3Systemdatatroubleshooting
Aspectsoftheinstallationcancauseproblemswiththedatasharedbetweenconnectedequipment.
Suchproblems,theirpossiblecausesandsolutionsaredescribedhere.
Transducer,instrument,engineorothersystemdataisunavailableatalldisplays.
Dataisnotbeingreceivedatthedisplay.
1.Checktherelevantproductandornetworkcablingandconnections(e.g.Sea Talkng
backbone)forsignsofdamageorcorrosion,andreplaceifnecessary.
Datasource(e.g.instrumentdisplayorengineinterface)isnotoperating.
1.Checkthesourceofthemissingdata(e.g.transducerorengineinterface)forsignsofdamage
orcorrosion,andreplaceifnecessary.
2.Ifpossible,checkthatthedatasourceiscorrectlypoweredandoperational.
3.Refertotheinstructionsprovidedwiththeequipmenttoensureithasbeencorrectlyinstalled.
Softwaremismatchbetweenequipmentmaypreventcommunication.
1.Ensureallproductshavethelatestsoftwareinstalled.
Transducer,instrumentorothersystemdataismissingfromsomebutnotalldisplays.
Connectionproblem.
1.Checktheproduct’sSeaTalkngspurcableandconnectionsforsignsofdamageorcorrosion,
andreplaceifnecessary.
Softwarecorruption.
1.Intheunlikelyeventthattheproduct’ssoftwarehasbecomecorrupted,trydownloadingand
installingthelatestsoftwarefromtheRaymarinewebsite.refertoyourMultifunctionDisplay’s
operationinstructionsfordetailsonupdatingsoftwareforSeaTalkngdevices.
2.Inthecaseofarestartloopattemptafactoryresetusingthefollowinginstructions:
p.54PerformingaFactoryReset
Softwaremismatchbetweenequipmentmaypreventcommunication.
1.Ensureallproductshavethelatestsoftwareinstalled.
Incorrectdatareported.
Transducercalibrationerror
1.Switchoffpowersupplytosystemandswitchbackonagain.
2.Re-calibrateorre-configuredatasourcefollowinginstructionsprovidedwiththerelevant
devices.
6.4Miscellaneoustroubleshooting
Miscellaneousproblemsandtheirpossiblecausesandsolutionsaredescribedhere.
Displaybehaveserratically.
Frequentunexpectedresetsorsystemcrashesandothererraticbehavior:
Intermittentproblemwithpowertothedisplay.
1.Checkrelevantfusesandbreakers.
2.Checkthatthepowersupplycableissoundandthatallconnectionsaretightandfreefrom
corrosion.
3.Checkthatthepowersourceisofthecorrectvoltageandsufficientcurrent.
Softwaremismatchbetweenequipmentmaypreventcommunication.
1.Ensureallproductshavethelatestsoftwareinstalled.
Corruptdata/otherunknownissue.
T roubleshooting
55