AppendixATechnical
specication
Nominalsupplyvoltage12or24Vdc
Operatingvoltagerange
10Vto32Vdc
Fuse/BreakersPowersupplyfuse:
•15A(SPX-10,SPX-SOL)
•40A(SPX-30)
SeaTalkPowerout•2Aat12V(fuseprotected
at2A)—SPX-10
•3Aat12V(fuseprotected
at3A)—AllexceptSPX-10
SeaTalk
ng
Powerout•2Aat12V(fuseprotected
at2A)—SPX-10
•3Aat12V(fuseprotected
at3A)—AllexceptSPX-10
Powerconsumption(standby)
300mA
SeaTalk
ng
LEN(Load
EquivalencyNumber)
1
GyroInternalGyroPlusttedas
standard
Environmentalconditions
operatingtemperature
non-operatingtemperature
relativehumiditylimitwater
protection
Installationenvironment
•Operatingtemperature:
-10ºCto+50ºC(14ºFto
122ºF)
•Storagetemperature:
-20ºCto+65ºC(-4ºFto
149ºF)
•Relativehumidity:max
95%
•Dripresistantwhen
mountedvertically
Dimensions
•Width:285mm(11.2in)
•Height:212mm(2.5in)
•Depth:65mm(8.3in)
Weight
•1.1kg(2.42lbs)—SPX-10
•2.2kg(4.85lbs)—SPX-30
DataConnections•NMEA0183:I/O4800
baud
•SeaTalk
ng
•SeaTalk
Otherconnections
Fluxgatecompass,Rudder
positionsensor,Sleepswitch,
Power,drivemotor,drive
clutch/SOLbypassvalve
Fastheadingoutput•NMEA0183—5Hz
•SeaTalk
ng
—10Hz
•NMEA2000—10Hz
Raymarinedrivecompatibility
X10X30XSOLENOID
SPX-10
•allType1drives/pumps
(excludingCRpumps).
Drivevoltagemustmatch
boat’ssupplyvoltage.
SPX-30
•allType1,Type2andType
3drives/pumps.Drive
voltagemustmatchboat’s
supplyvoltage.
SPX-SOL
•CRpumpsandsolenoid
drive
Drivecurrentoutput
SPX-10
•Continuous10Aatsupply
voltage
•Peak(Limit)25A
•Continuous30Aatsupply
voltage(SPX-30)
SPX-30
•Continuous30Aatsupply
voltage(SPX-30)
•Peak(Limit)50A
DriveclutchoutputX10X30
XSOLENOID
•2.0Aat12/24Vselectable
(SPX-10,SPX-SOL)
•3.0Aat12/24Vselectable
(SPX-30)
EMCcompliance:•Europe:2004/108/EC
•AustraliaandNewZealand:
C-Tick,ComplianceLevel
2
Technicalspecication
33