2 ST60 Graphic Display Commissioning Guide
receive a satisfactory power supply. The requirements for power connections
are detailed in the following table.
:
Connection procedure
To connect your ST60 Graphic Display:
1. Ensure that:
• Power to the existing SeaTalk system is switched off.
• The conditions described under Power requirements are fulfilled.
2. Plug the SeaTalk cable(s) from the rear of the display into a vacant
SeaTalk connector on an adjacent instrument. You can either break the
existing SeaTalk chain to connect as shown in the following illustration,
or connect to an existing product at the end of the SeaTalk bus.
SeaTalk cable run No. of instruments Power connections
Up to 10 m 13 maximum To one end of the system
26 maximum To both ends of the system
Up to 20 m 7 maximum To one end of the system
13 maximum To both ends of the system
D4311-1
5 A fused,
12 V dc supply
(typically provided
by autopilot)
Red
Screen
Red
Screen
1234
Instruments
5 to 16
17
18
19
20
SeaTalk power connections
81228_1.book Page 2 Wednesday, November 19, 2003 10:29 AM