- 9 - | Page
Evaporator coil iced over. Unplug unit and allow coil to
defrost. Make sure thermostat is
not set too cold. Ensure that
door gasket(s) are sealing
properly.
Cabinet
temperature
is too warm.
Thermostat set too warm.
B
locking air flow.
Excessive amount of warm product
placed in cabinet.
Fuse blown or circuit breaker tripped.
D
irty condenser coil.
Prolonged door opening or door ajar.
E
vaporator coil iced over.
Set thermostat to lower
temperature.
Re-arrange product to allow for
proper air flow. Make sure there
is at least four inches of
Clearance from evaporator.
Allow adequate time for
product to cool down.
Replace fuse or reset circuit
breaker.
Clean the condenser coil.
Ensure doors are closed when
not in use. Avoid opening doors
for long periods of time.
(see above)
Cabinet is
noisy.
Loos
e part(s).
Tubing vibration.
Fan is
unbalanced.
Loc
ate and tighten loose
part(s).
Ensure tubing is free from
contact with other tubing or
components.