PIT FIRE SERIES
INSTALLATION & OPERATING MANUAL
The Real Flame Pit Fire series are suitable to be installed into a masonry or
fireproof base, in outdoor installations only. Designed to operate on Natural
or LPG gases only. Approval no.GMK10130
Installed primarily as a decorative appliance. Not certified as a Space Heater.
VERSION 10
Question and Answer IconNeed help?

Do you have a question about the Real Flame PIT FIRE SERIES and is the answer not in the manual?

Real Flame PIT FIRE SERIES Specifications

General IconGeneral
BrandReal Flame
ModelPIT FIRE SERIES
CategoryOutdoor Fireplace
LanguageEnglish

Summary

Warranty Information

Warranty Coverage

Details the warranty coverage for the Real Flame gas burner and its parts.

Product Registration

Explains the mandatory process for registering the product to receive warranty benefits.

Warranty Exclusions

Lists conditions under which Real Flame is not obligated to replace or repair the product.

Liability Limitations

Defines the scope of warranty liability, limited to repair or replacement.

Warranty Claim Procedure

Outlines the procedure and required information for making a warranty claim.

Installation Notice

Initial Use Note

A slight smell may occur during initial use due to paint curing.

Important Safety Notices

General Appliance Safety Rules

Covers placement, flammable materials, aerosols, and modifications.

Luminous Flame Characteristics

Notes on luminous flames and normal carbon deposits, not covered by warranty.

Warning

Naked Flame Hazard Awareness

Exercise caution with naked flame, especially around children and the infirm.

Appliance Purpose Disclaimer

Primarily decorative, not certified as a space heater.

Installation Instructions

Location and Clearances

Select outdoor location, ensure clearances from combustibles and proper enclosure ventilation.

Enclosure Ventilation Requirements

Details requirements for ventilation in enclosures for natural dispersion of gases.

Installation Instructions (continued)

Enclosure Design Examples

Illustrates various enclosure types (Examples 1-5) for safe appliance installation.

Construction of Enclosure

Enclosures must be stable, non-combustible, above ground, with adequate drainage and specific venting.

Lighting Instructions

Step-by-step guide for lighting the pilot and main burner.

Installation Instructions (continued)

Optional Ignition Methods

Details options for 240V/24V ignition switches and air pressure switches.

Ventilation and Gas Control Placement

Ensures proper ventilation clearance and safe placement of gas controls to prevent explosion risk.

Installation Instructions (continued)

Examples of Enclosures (Diagrams)

Illustrates enclosure setups with power isolation, isolation valves, and access panels.

Installation Instructions (continued)

Optional Glass Surrounds Dimensions

Provides dimensions for optional glass surrounds and their installation notes.

Installation Instructions (continued)

Glass Surround Fitment

Details when optional glass surrounds are required and how to fit them.

Portable Enclosure Notes

Refers to notes on the next page regarding gas cylinder placement for portable units.

Installation Instructions (continued)

LPG System: Cylinder Retention

Covers cylinder retention for LPG systems.

LPG Enclosure Ventilation

Specifies ventilation requirements for LPG cylinder enclosures.

Cylinder Valve Accessibility

Ensures the cylinder valve is accessible for manual operation.

LPG Cylinder Installation Guidelines

Guidelines for safely installing LPG cylinders on a firm, level base.

LPG Cylinder Clearances

Defines safe clearance distances around LPG cylinders and ignition sources.

Installation Instructions (continued)

Masonry/Brickwork Enclosure Construction

Details typical masonry enclosure requirements including height, access, and ventilation.

Fabricated Enclosure Construction

Details typical fabricated enclosure requirements including barriers, ventilation, and access.

Enclosure General Notes

Key notes on enclosure venting, stability, media, LPG storage, and radiant heat effects.

Installation Instructions (continued)

Gas Type and Isolation Valve Check

Verify gas type and ensure gas isolation valve is accessible and protected.

Wiring Safety and Installation Practices

Ensure wiring is safe, customer is trained, and installation codes are followed.

Pre-Operation Testing and Checks

Perform gas leak tests and check/adjust gas pressures before operation.

Continuous Supervision Requirement

Appliance must be supervised at all times during operation.

Wiring Diagrams

240V Directly Wired Diagram

Illustrates the wiring configuration for a 240V direct connection.

24V Wall Mounted Transformer Kit Diagram

Shows the wiring for a 24V system with a wall-mounted transformer.

Commissioning Procedure

Pre-Media Installation Checks

Checks for gas leaks, lighting, and burner pressures before installing media.

Volcanic Rock Media Installation

Instructions for filling the tray with volcanic rock, avoiding pilot area.

Volcanic Rock Media Warning

Warns about spitting from new/wet media and recommends initial firing.

Media Installation (continued)

Glass Media Installation

Instructions for laying glass media over volcanic rock, avoiding pilot area and overfilling.

Glazed Pebbles Installation

Instructions for filling with glazed pebbles, avoiding pilot area and overfilling.

Glazed Pebble Media Warning

Warns about spitting from new/wet media and recommends initial firing.

Media Installation (continued)

Volcanic Rock with Ceramic Logs

Instructions for using volcanic rock with ceramic logs, avoiding pilot area and overfilling.

Ceramic Log Media Warning

Warns about spitting from new/wet media and recommends initial firing.

Ceramic Logs Operational Note

Notes on live fuel effect, luminous flames, carbon deposits, and log cleaning.

Operation - User Instructions

General Operation Precautions

Do not operate if gas is smelled, ensure fire is covered when not in use, avoid water submersion.

Lighting Procedure

Step-by-step guide to ensure gas supply, electrical supply, and ignite pilot/burner.

Media Drying Warning

New/wet media may spit; maintain safe distance until media is dry.

Safety and Maintenance Notes

Alerts on high temperatures, recommends guards, and schedules periodic servicing.

Troubleshooting

Pilot Light Issues

Troubleshooting for pilot not lighting, checking gas, electrical, and electrode.

Main Burner Ignition Failure

Possible causes include blocked pilot flame or faulty thermogenerator.

Main Flame Size and Appearance

Addresses issues with flame size (too little/large) and color (yellow/tall).

Conversion Details

Natural Gas to Propane Conversion Steps

Detailed procedure for converting the appliance from natural gas to propane.

Parts List

Valve Component

Identifies the main valve component.

Pilot Assemblies

Lists pilot assemblies for both natural gas and propane.

Injector Components

Lists injectors for natural gas and ULPG.

Gas Controller Module

Identifies the gas controller module CNE CCA-0835.

Cheminee Pty Ltd

Contact Information

Provides email, website, phone, and fax details for the supplier.

Showroom Location

Gives the address of the physical showroom.