2
BASIN COVER
* DISCHARGE OF BASIN IS
1-1/2" FNPT.
* UNION
8 FT. POWER CORD
11.56
INLET OF BASIN
IS 1-1/2" FNPT.
* VENT OF BASIN
IS 1-1/2" FNPT.
13.38
15.125
CHECK VALVE
ASSEMBLY
REUSABLE SEAL
* ALL ITEMS OUTSIDE OF BASIN MUST BE CUSTOMER SUPPLIED
POWER CORD SEAL INCLUDED
PUMP DISCHARGE IS
1-1/2" FNPT
FROM PUMP BODY
* 1-1/2" UNION
* 1-1/2" UNION
BASIN
1-1/2" DISCHARGE PIPE
AUTOMATIC SUMP PUMP
BASIN COVER/SEAL DETAIL
RIBS OF SEAL RING
TOWARD BASIN
RE-USABLE SEAL RING
A-N301
A-N301
REVISED 17MAR11
DISCHARGE PIPING
VENT PIPING
11.8960
SINK TRAY ASSEMBLY
1, Turn Basin Lid over and "lay" in the seal as shown with ribs on seal up. From the bottom
side, through cover, insert (8) 1/4 inch screws through the holes in the seal.
2. Install check valve and discharge pipe into pump. Use Teon tape on the pipe threads.
Place pump in the basin and pull power cord through the power cord hole in the cover.
Allow approximately 12" of cord between pump and Power cord seal. Slip power cord seal
DISCHARGE
SOCKET
VENT
1
4
" Screws
Ribs on Seal
Facing Up
1.866
1.866
2.906
2.906
1-1/2"
FNPT
THREADED
SMOOTH
NO
THREADS
POWER
CORD
HOLE
EITHER HOLE CAN
BE USED AS VENT
OR DISCHARGE.
COVER TOP VIEW
12.00
Power Cord Seal
Automatic
Sump Pump
over pump power cable and install power cord seal into power cord hole in cover. Identify
opening for pump discharge pipe and be certain that discharge pipe is inserted into
socket in cover and that this is the discharge pipe and not the vent pipe. Install cover
and tighten bolts.
RE-USABLE SEAL
COVER
FIGURE 1 - TYPICAL INSTALLATION