11. While connecting the radiator to electric installation ensure that the cur-
cuit has a 30 mA residual-current circuit breaker and an appropriate over-
current circuit breaker. With the permanent installation (cable connec-
tion without plug) it is also mandatory to provide an omnipolar cut-o
switch with a minimum contact opening of 3 mm for disconnecting the
device on all poles.
12. The device version labelled PB can be installed in bathrooms in zone 1,
as dened by applicable law, subject to any additional regulations con-
cerning electrical installations in wet areas.
Other versions of the device can be installed in Zone 2 or beyond.
13. The device is recommended for use solely as described in the manual.
14. Ensure that the heater has been installed on a wall in accordance with
its installation manual.
15. Please forward this instruction manual to the end user.