USER INSTRUCTIONS i700A/B & i702C
Thank you for purchasing the Reliable™ i700A/B or i702C series steam
cleaner. Please follow the instructions carefully. With proper care and
maintenance, your steamer will provide years of dependable service.
Your steamer is supplied with a safety cap on the blow-down valve (right side
of tank), as well as a plastic tube and fitting to secure the tube. Please
remove the safety cap and install the tube and fitting. This will allow you to
follow the cleaning procedure described at the bottom of the page. If there is
a problem with the blow-down valve (leaking) you can use the safety cap to
prevent water from leaking until you have the valve replaced.
1. Unscrew the security cap (on the top) and fill the steamer with a
maximum of 7 liters of water. For the i700A or i702C screw in the
adjustable nozzle and tighten securely. Insert the 4-pin receptacle
provided for the plug on the electronic foot pedal. For the i700B or
i702C, connect the steam gun by plugging it in the quick disconnect
fitting on the solenoid valve (you can also install the hose support wand
at this time as well) and insert the 4-pin connector in the receptacle
provided.
2. Plug the steam generator into the main power supply.
3. Switch on the steam generator by pressing the button "boiler" and the
steam by pressing the “steam “ button.
4. Wait until the pressure reaches 4-5 bar (60-70 lbs) (about 15 min.).
5. Press the foot pedal or the (red) steam button on the steam gun and
regulate the desired steam quantity by turning the valve handle situated
behind the solenoid valve on the steam generator.
6. Every 30 minutes check the water level in the glass to ensure that the
water is not below the minimum level mark.
If you notice a decrease in steam pressure when you first use the steamer,
this is because the tank is full of air. In order to have plenty of steam (after
you have depressed the foot pedal or steam gun) wait until the pressure
goes back up to the maximum level before you begin.
If during use the steam flow ceases and the low water button lights up, it
means that there's no more water in the steam generator. In order to start
steaming again, switch off the "boiler" button, slowly unscrew the security