RX Family ADC Module Using Firmware Integration Technology
R01AN1666EJ0220 Rev. 2.20 Page 66 of 74
Dec 01, 2016
Some features may not be used with others. The following table illustrates this.
X *B X X
X X X X X
*B *S *A
*A
Detection
X X X
X - Combination may not be used. For example, ANEX may not be used with group scan modes, Self-Diagnosis,
sensors or Disconnect Detection Assist.
*A - Sample and Hold channels must be in Group A.
*B - Sample and Hold channels must be in Group B or Group C.
*S - Sample and Hold channels cannot be split across groups.
Special Notes (RX130/RX230/RX231):
This function does not support following features.
• Compare function window B
• Compare function window A/B composite condition setting
Special Notes (RX130/RX230/RX231/RX64M/RX71M/RX65x):
When using the comparison, configure the comparison after the channel configuration.
This function does not support following feature.
• Group A priority control setting
Special Notes (RX63x):
Only AN008 to AN020 can be used for setting the number of sampling states. AN000 to AN007 are fixed to 20 states
regardless of the setting.
Special Notes (RX110/RX111/RX113):
For temperature sensor and internal reference voltage, the number of sampling states must be set to 5 µs or greater.