EN
Problem Possible cause Corrective action
Lamp does not
go on.
Power cord not plugged in.
Fluorescent tube defective.
• Faulty electronics.
Fluorescent tube not prop-
erly seated in the socket.
Plug the power cord into the wall outlet.
Replace the fluorescent tube (refer to Sec. 5.6).
Call for service to replace the electronics, or refer to the spare
parts list.
Refer to Sec. 5.6, “Fluorescent Lamp Installation”.
Compressed air
leaking from the
foot switch.
Pneumatic hoses re-
versed.
Reverse the connections.
Foot switch fails
to switch on.
No pressure at the com-
pressed air connection.
Pneumatic hoses are
kinked.
Inspect the compressed air lines and/or the compressor.
Reposition the hoses.
Foot switch hoses
cannot be discon-
nected from the
unit.
Push-in connection is not
released (Fig. 1).
Press the push-in connection ring on the hose side firmly
while pulling on the hoses.