2. Check the air tubing and replace it if there are any holes, tears or cracks.
3. Check the air filter and replace it at least every six months. Replace more often if there are any
holes or blockages by dirt or dust.
To replace the air filter:
1. Open the air filter cover and remove the old air filter.
The air filter is not washable or reusable.
2. Place a new air filter onto the air filter cover and then close it.
Make sure the air filter is fitted at all times to prevent water and dust from entering the device.
Reassembling
When the humidifier and air tubing are dry, you can reassemble the parts.
1. Connect the air tubing firmly to the air outlet located on the rear of the device.
2. Open the humidifier and fill it with room temperature water up to the maximum water level
mark.
3. Close the humidifier and insert it into the side of the device.
4. Connect the free end of the air tubing firmly onto the assembled mask.
Therapy data
Your AirCurve 10 device records your therapy data for you and your care provider so they can view
and make changes to your therapy if required. The data is recorded and then transferred to your care
provider wirelessly or via an SD card.
Data transmission
Your AirCurve 10 device has the capability of wireless communication so that your therapy data can
be transmitted to your care provider to improve the quality of your treatment. This is an optional
feature that will only be available if you choose to benefit from it. It also allows your care provider to
update your therapy settings in a more timely manner or upgrade your device software to ensure
you receive the best therapy possible.
The data is usually transmitted after therapy has stopped. In order to make sure that your data is
transferred, leave your device connected to the mains power at all times and make sure that it is not
in Airplane Mode.
Notes:
Therapy data might not be transmitted if you use it outside of the country or region of purchase.
Devices with wireless communication might not be available in all regions.

Other manuals for ResMed AirCurve 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ResMed AirCurve 10 and is the answer not in the manual?

ResMed AirCurve 10 Specifications

General IconGeneral
Sound Level26 dBA
Ramp FeatureYes
Device TypeBi-Level Positive Airway Pressure Device
Weight1248 g
HumidificationIntegrated humidifier
ConnectivitySD card
Mode of OperationS
Ramp Time0 to 45 minutes
Data StorageSD card
DisplayColor LCD screen
CompatibilityCompatible with masks
Power Supply100–240V AC, 50–60Hz, 2.0A

Related product manuals