Transport and storage 23/60
RE 91616-01-B/10.2014, A6VE Series 65 and 71, Bosch Rexroth AG
6.2 Storing the axial piston unit
The storage areas must be free of corrosive materials and gases.
To prevent damage to the seals, ozone-forming equipment (e.g. mercury-vapor
lamps, high voltage equipment, electric motors, sources of electrical sparks or
electrical discharge) must not be operated in storage areas.
The storage areas must be dry.
Ideal storage temperature: +5 °C to +20 °C.
Minimum storage temperature: -50 °C.
Maximum storage temperature: +60 °C.
Avoid significant exposure to light (e.g. bright windows or direct fluorescent
lighting).
Do not stack axial piston units and store them shock-proof.
Do not store the axial piston unit on the drive shaft or fitting, e.g. sensors or valves.
For further storage conditions, see Table 8.
Check the axial piston unit monthly to ensure proper storage.
The axial piston units are provided ex-works with corrosion protection packaging
(corrosion protection film).
Table 8 lists the maximum permissible storage times for an originally packed axial
piston unit as per data sheet 90312.
Table 8: Storage time with factory corrosion protection
Storage conditions Standard corrosion protection Long-term corrosion
protection
Closed, dry room, uniform
temperature between +5°C and
+20°C. Undamaged and closed
corrosion protection film.
Maximum 12 months Maximum 24 months
Entitlement to warranty will be rendered void if the requirements and storage
conditions are not adhered to or after expiration of the maximum storage time
(see Table 8).
Procedure after expiry of the maximum storage time:
1. Check the entire axial piston unit for damage and corrosion prior to installation.
2. Check the axial piston unit for proper function and leaks during a test run.
3. If the storage time exceeds 24 months, the shaft seal must be replaced.
After expiry of the maximum storage time, we recommend that you have the axial
piston unit inspected by your responsible Bosch Rexroth Service partner.
In the event of questions regarding repair and spare parts, contact your responsible
Bosch Rexroth Service partner or the service department of the manufacturer's plant
for the axial piston unit, see chapter 10.5 “Spare parts” on page 49.
Requirements
After delivery

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REXROTH A6VE Series 71 and is the answer not in the manual?

REXROTH A6VE Series 71 Specifications

General IconGeneral
BrandREXROTH
ModelA6VE Series 71
CategoryEngine
LanguageEnglish

Related product manuals