Installation 25/60
RE 91616-01-B/10.2014, A6VE Series 65 and 71, Bosch Rexroth AG
7 Installation
Prior to installation, the following documents must be available:
Installation drawing for axial piston unit (can be obtained from your responsible
contact person at Bosch Rexroth)
Hydraulic circuit diagram for the axial piston unit (in the installation drawing)
Hydraulic circuit diagram for the machine/system (available from the machine/
system manufacturer)
Order confirmation (contains the order-related technical data for your axial piston
unit)
Data sheet of the axial piston unit (contains the permissible values of technical data)
7.1 Unpacking
The axial piston unit is delivered in a corrosion protection film made of polyethylene
material(PE).
CAUTION! Danger from parts falling out.
If the packaging is not opened correctly, parts may fall out and damage the parts or
even cause injuries.
Place the packaging on a flat and solid surface.
Only open the packaging from the top.
Remove the packaging from the axial piston unit.
Check the axial piston unit for transport damage and completeness, see chapter4
“Scope of delivery” on page 17.
Dispose of the packaging material according to the national regulations in your
country.
7.2 Installation conditions
The installation location and position of the axial piston unit essentially determine
the procedures during installation and commissioning (such as when filling and air
bleeding the axial piston unit).
Fix the axial piston unit so that the expected forces and torques can be
transferred without any danger. The machine/system manufacturer is responsible
for dimensioning the fasteners.
Observe the permissible radial forces on the drive shaft when transferring output
drive with radial force loading (belt drives). If necessary, the belt disc must be
separately mounted.
Make certain that the axial piston unit is air bled and filled with hydraulic fluid
during commissioning and operation. This is also to be observed following
relatively long standstill periods as the axial piston unit may empty via the
hydraulic lines.
The case drain fluid in the case interior must be directed to the reservoir via the
highest case drain port. Use the line size which is appropriate for the port.