40/60 Installation
Bosch Rexroth AG, A6VE Series 65 and 71, RE 91616-01-B/10.2014
7.5 Performing flushing cycle
In order to remove foreign particles from the system, Bosch Rexroth recommends a
flushing cycle for the entire system before the first commissioning. To avoid internal
contamination, the axial piston unit must not be included in the flushing cycle.
The flushing cycle must be performed with an additional flushing unit. Follow the
instructions of the flushing unit's manufacturer for the exact procedure during the
flushing cycle.