10-2 MKD112 Synchronous Motors MKD
19.05.2004 Version7.0 DOK-MOTOR*-MKD*******-PR07-EN-P
Descri
p
tion S
y
mbol Unit MKD112A-058
Coolin
g
mode Natural Natural Surface
Motor overtemperature 60K 100K 60K /100K
Electric
p
arameters
Characteristic motor speed n
K
min
-1
4000
Continous tor
ue at standstill M
dN
Nm 15,0 17,0 22,5
Continous current at standstill I
dN
A 17,1 20,1 25,7
Peak current I
ma
x
A 77,0
Tor
q
ue constant at 20°C
1
)
K
m
Nm/A 0,98
Volta
g
e constant at 20°CK
E
(
eff
)
V/1000min
-1
89
Windin
g
resistance at 20°CR
12
0,86
Windin
g
inductace L
12
mH 7,8
Number of pole pairs p 4
Rated data
2
)
Rated speed n
N
min
-1
3500 3500 3500
Rated tor
q
ue M
N
Nm 7,3 13 17,8
Rated current I
N
A 5,9 10,9 14,4
Rated power P
N
kW 3,2 6 8,1
Rated volta
g
eU
N
V 324 344 363
Rated fre
q
uenc
y
f
N
Hz 233 233 233
Mechanical
p
arameters
Rotor inertia J
M
k
g
m² 110,0 x 10
-4
Theoretical maximum tor
q
ue M
ma
x
Nm 54
Minimum strand cross-sectíon
4
)
Smm
2
1,5 1,5 2,5
Thermal time constant T
th
min404020
Maximum speed n
ma
x
min
-1
4500
Motor mass
3
)
5
)
mk
g
23,0
Perm. stora
g
e and transport temp. T
L
°C -20 to +80
Permissible ambient temperature
6
)
T
um
°C 0 to 40
Max. setup hei
g
ht
6
)
h m 1000 above NN
Protection cate
g
or
y
7
)
IP65
Insulation class
(
accordin
g
to DIN VDE 0530 Part 1
)
F
Housin
g
coat Prime coat black in a/w RAL 9005
1
)
2
)
3
)
4
)
5
)
6
)
7
)
K
m
is to be used for calculations with crest values (I
dN
, I
max
). For calculations with root-mean-square values (rated data), the torque
constant K
m
must be multiplied by a factor of
2
.
Values determined according to EN 60034-1. Current and voltage specified as root-mean-square values.
Use the declared value in bracket for motors holding brake.
Applicable to REXROTH INDRAMAT cables. Rated according to VDE0298-4 (1992) and installation type B2 according to EN 60204-
1 (1993) at an ambient temperature of 40 °C.
Without blower unit.
If the limits specified are exceeded, the performance data must be reduced if necessary. For reduction factors, refer to the chapter
entitled Environmental Conditions.
Provided the power and encoder cables are mounted properly
Fig. 10-2 Technical data MKD112A-058