HEAT PUMP AND TANK ASSEMBLY
24
4. Connect the mains power supply wiring to the terminal block and earth connection inside of the lower
front cover.
Secure the conduit to the side of the storage tank with a saddle clamp.
The saddle clamp must be positioned over the pilot holes provided, otherwise the conduit will
interfere with the heat pump module installation.
Refer to “Connections – Electrical” on page 33.
Note: The power supply to the water heater must not be switched on until the installation is complete,
the water heater is filled with water and a satisfactory megger reading is obtained.
Step 4
Connect wiring and secure conduit with saddle clamp
5. Refit the lower front cover.
6. Position the heat pump module near its installed position at the storage tank and remove the carton.
CAUTION: The heat pump module weighs approximately 48 kg. Use the hand holes provided in the
sides of the packaging. Good lifting practice should be followed.