11. Retrieve the loose ends of the two flexible braided hoses from within the heat pump module.
12. Attach the flexible braided hose from the bottom of the heat exchanger and marked “INLET” in blue on
its connection, to the bottom connection on the storage tank.
Tighten the swivel nut on the hose using a 24 mm spanner.
Tape or sealant is not required.
Position the hose such that when the heat pump module is moved and secured to the tank, it does
not kink.
13. Attach the flexible braided hose from the top of the circulator and marked “OUTLET” in red on its
connection, to the top connection on the storage tank.
Tighten the swivel nut on the hose using a 24 mm spanner.
Tape or sealant is not required.
Position the hose such that when the heat pump module is moved and secured to the tank, it does
not kink.
Step 12 Step 13
attach flexible hose to inlet attach flexible hose to outlet
14. Check to ensure the flexible hoses are not kinked.