TM063 701, 702 & 703 Series Boiling Water Unit Service Instructions
Revision D: Feb 2017
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
Fault Finding Tests 3B 6A
Test 3B (25 & 40L models)
Test 4
Using a multimeter on the AC voltage scale,
measure between the Active and Neutral
terminals on the control board. The following
result should be obtained:
Control board Active to Neutral
230-240 Volts AC.
Disconnect the boiling water probe at
control board and remove probe from
housing. Using a megger on the 500V scale,
megger between the probes of the level probe.
The following result should be obtained:
> 1 Mega-ohm.
Test 5A (3 15L models only)
Test 5B (25 & 40L models)
Disconnect the red wire from the boiling water
element E.C.O. and using a multimeter on the
ohms scale, measure between the terminals of
the boiling water E.C.O. The following result
should be obtained:
0 ohms (E.C.O. has not tripped).
Disconnect the red and blue wire from the
E.C.O. and using a multimeter on the ohms
scale, measure between the L1 and L2
terminals, and the N1 and N2 terminals of the
E.C.O. The following result between should be
obtained:
L1-L2: 0 ohms (E.C.O. has not tripped).
N1-N2: 0 ohms (E.C.O. has not tripped).