30
TM061 Rheem 27 Water Star Service Instructions – Issued: 11/10
REV A Issued 08/13
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
Fault Finding Tests 8, 9 & 11
Conduct test during ignition attempt.
Using a multimeter set on the AC volts scale, measure the voltage between the two red wires at
base of the ignition module.
Normal voltage should be between 90 – 110VAC.
Conduct test with water flowing.
Using a multimeter set on the DC volts scale,
measure the voltage with multi-pin connector
plugged into terminal W on control PCB.
Using a multimeter set on the kilo-ohms scale,
measure the resistance with multi-pin
connector unplugged from terminal W on
control PCB.
0.8 kilo-ohms
to
2.4 kilo-ohms