IKONIC Tankless Water Heater Service Manual
52
2.2 ERROR CODE LIST
A070 ERROR CODE
Microcomputer Abnormality.
If the microcomputer on the control board is not work-
ing properly, the water heater displays the “A070” error
code on the User Interface.
Diagnostic check items
Control board
ERROR CODE DIAGNOSTICS
Turn Power OFF
Turn power ON and operate unit.
If "A070" error code is appeared, please
replace the control board.