IKONIC Tankless Water Heater Service Manual
69
FLAME AND IGNITER ROD
HOW TO REMOVE COMPONENTS
1. Remove the hook lm part of the Over Heat Limiter
(OHL ). DO NOT cut the lm.
2. Remove flame rod and igniter rod wires wire from the
rods.
3. Remove 3 screws from flame rod bracket, and pull
the rod bracket.
NOTE: When reassembling flame and igniter rods,
please use a spare gasket if the condition of the gasket
is not good.
The spare gasket is located at lower left in the unit.