EasyManua.ls Logo

Rheem R801TA050314MSA - Furnace Dimensions and Clearances; Clearance to Combustible Material

Rheem R801TA050314MSA
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
BOTTOM
TOP
LEFT SIDE FRONT RIGHT SIDE
GAS
CONNECTION
ELECTRICAL CONNECTION
LINE VOLTAGE
ELECTRICAL CONNECTION
LOW VOLTAGE
OPTIONAL
GAS CONNECTION
OPTIONAL LOW
VOLTAGE WIRING
OPTIONAL LINE VOLTAGE
WIRING
A
I
R
F
L
O
W
RETURN
AIR
SUPPLY
AIR
HOT
MODEL A B C D E F RIGHT SIDE BACK TOP FRONT VENT
5 14 13 27/32 10 5/8 11 1/2 1 7/8 0 4 0 1 3 6 85 lbs.
7 17 1/2 16 11/32 12 3/8 15 2 1/2 0 3 0 1 3 6 105 lbs.
12 24 1/2 23 11/32 15 7/8 22 2 1/2 0 0 0 1 3 6 140 lbs.
15 24 1/2 23 11/32 15 7/8 22 2 1/2 0 0 0 1 3 6 150 lbs.
MAY REQUIRE 3" TO 4" OR 3" TO 5" ADAPTER.
4" ADAPTER INCLUDED WITH (-)801P UNITS.
MAY BE 0" WITH TYPE B VENT.
MAY BE 1" WITH TYPE B VENT.
LEFT SIDE
REDUCED CLEARANCE (IN.)
SHIP
WGTS.
FIGURE 4
UPFLOW/HORIZONTAL DIMENSIONS
Location
REDUCED CLEARANCE (IN.)
Model A B C D E F
Left Right
Back Top Front Vent
Ship.
Side Side Wgts.
50K 14 12
27
/32 10
5
/8 11
1
/2 1
7
/8 0 4 0 1 3 6 85 lbs.
75K 17
1
/2 16
11
/32 12
3
/8 15 2
1
/2 0 3 0 1 3 6 105 lbs.
100K 21 19
27
/32 14
1
/8 18
1
/2 2
1
/2 0 0 0 1 3 6 120 lbs.
125K 24
1
/2 23
11
/32 15
7
/8 22 2
1
/2 0 0 0 1 3 6 140 lbs.
150K 24
1
/2 23
11
/32 15
7
/8 22 2
1
/2 0 0 0 1 3 6 150 lbs.
CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES)
UPFLOW/HORIZONTAL MODELS
May require 3” to 4” or 3” to 5” adapter.
4” adapter optional.
May be 0” with type B vent.
May be 1” with type B vent.
ST-A1220-04

Table of Contents