10
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEZ
RCFL-H*3617
RGGE-06?MCK?
1 17900 [5.2] 9700 [2.8]
34200 [10.0] 14.5 11.5
725 [342] 71
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGGE-07?MCK?
1 18200 [5.3] 9600 [2.8]
34000 [10.0] 14.5 11.5
750 [354] 71
2 22400 [6.6] 11600 [3.4] 1025 [484] 72
RGJF-06?MCK?
1 17900 [5.2] 9700 [2.8]
34200 [10.0] 14.5 11.5
725 [342] 71
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGJF-07?MCK?
1 18200 [5.3] 9600 [2.8]
34000 [10.0] 14.5 11.5
750 [354] 71
2 22400 [6.6] 11600 [3.4] 1025 [484] 72
RGLE-07?AMK?
1 18200 [5.3] 9600 [2.8]
34200 [10.0] 14.5 12
750 [354] 71
2 22600 [6.6] 11600 [3.4] 1025 [484] 72
RGPE-05?BMK?
1 19500 [5.7] 9100 [2.7]
34600 [10.1] 14 11
900 [425] 71
2 23700 [6.9] 10900 [3.2] 1200 [566] 72
RGPE-07?AMK?
1 17900 [5.2] 9700 [2.8]
34000 [10.0] 14.5 11.5
725 [342] 71
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
RGRM-04?MAE?
1 18000 [5.3] 9600 [2.8]
34000 [10.0] 14 11.5
750 [354] 71
2 22400 [6.6] 11600 [3.4] 1025 [484] 72
RGRM-06?MAE?
1 18200 [5.3] 9600 [2.8]
33800 [9.9] 14 11.5
775 [366] 71
2 22100 [6.5] 11700 [3.4] 1000 [472] 72
RGRM-07?MAE?
1 18300 [5.4] 9500 [2.8]
33800 [9.9] 14 11
800 [378] 71
2 22200 [6.5] 11600 [3.4] 1025 [484] 72
RGTM-06?MAE?
1 19500 [5.7] 9100 [2.7]
34000 [10.0] 14 11.5
900 [425] 71
2 22400 [6.6] 11600 [3.4] 1025 [484] 72
ROCA-070E03
1 18500 [5.4] 9500 [2.8]
34000 [10.0] 14.5 12
800 [378] 71
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
ROCA-070E04
1 18500 [5.4] 9500 [2.8]
34000 [10.0] 14.5 12
800 [378] 71
2 22300 [6.5] 11700 [3.4] 1000 [472] 72
ROLA-070E03
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 14.5 11.5
900 [425] 71
2 23800 [7.0] 11000 [3.2] 1175 [554] 72
ROLA-070E04
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 14.5 11.5
900 [425] 71
2 23800 [7.0] 11000 [3.2] 1175 [554] 72
RCFL-H*3617+RXMD-C06 Coil Only
1 18900 [5.5] 9100 [2.7]
34200 [10.0] 13 11
925 [437] 71
2 23000 [6.7] 11200 [3.3] 1075 [507] 72
RCFL-H*3621
RGFE-06?MCK?
1 18900 [5.5] 9300 [2.7]
34400 [10.1] 14 11
875 [413] 71
2 23500 [6.9] 10900 [3.2] 1200 [566] 72
RGFE-07?MCK?
1 18900 [5.5] 9300 [2.7]
34400 [10.1] 14 11
875 [413] 71
2 23600 [6.9] 10800 [3.2] 1225 [578] 72
RGFE-09?ZCM?
1 19100 [5.6] 9300 [2.7]
34800 [10.2] 14.5 11.5
875 [413] 71
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
RGFE-10?ZCM?
1 19500 [5.7] 9100 [2.7]
34800 [10.2] 14.5 11.5
900 [425] 71
2 24000 [7.0] 10800 [3.2] 1225 [578] 72
RGFG-06?MCK?
1 18900 [5.5] 9300 [2.7]
34400 [10.1] 14 11
875 [413] 71
2 23500 [6.9] 10900 [3.2] 1200 [566] 72
RGFG-07?MCK?
1 18500 [5.4] 9500 [2.8]
33800 [9.9] 14.5 11.5
800 [378] 71
2 22100 [6.5] 11700 [3.4] 1000 [472] 72
RGFG-09?ZCM?
1 19100 [5.6] 9300 [2.7]
34800 [10.2] 14.5 11.5
875 [413] 71
2 23900 [7.0] 10900 [3.2] 1200 [566] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions