8. TROUBLESHOOTING
If these solutions, below, do not work, contact your dealer.
Do not attempt to repair the heater yourself.
Failure Reason Solution
Swimming
Pool Heat
Pump Does
Not Run
Main power o󰀨
Wait for the power to be
restored
Power switch
is o󰀨
Turn on switch
Fuse burnt Replace fuse
Circuit breaker
tripped
Turn circuit breaker back on
Heat Pump
Runs but
Does Not
Heat
Air inlet blocked Remove obstructions
Air outlet
blocked
Remove obstructions
3-minute
protection
Please wait more than 3
minutes for warming to start
Temp set too
low
Set temperature setting
Table G. Common Faults
Fault Codes
Failure Code Failure Description
E1 High pressure protection
E2 Low pressure protection
E3 Low water pressure protection
E4
Single phase unit: loose wire terminal at
PROT2 on the PC board
Three phase unit: 3 phase sequence
protection
P1 Pool water temp sensor failure
P2
Exhaust temp sensor failure (cooling coil
temp for heat and cooling models only)
P3 Heating coil pipe temp sensor failure
P4 Gas return temp sensor failure
P5 Air temp sensor failure
E6
Compressor exhaust overload protection
212°F (100°C) (Heating models only)
P7
When air temp <32°F (0°C), the unit is in
auto-stop protection mode, or anti-freeze
mode (not a failure)
HEAT ashing Defrosting (not a failure)
Table H. Fault Codes - On/O󰀨 Models Only
No. Display Non-Failure Description
1 E3 No water protection
2 E5 Power supply excesses operation range
3 E6
Excessive temp di󰀨erence between inlet
and outlet water
(insu󰀩cient water ow protection)
4 Eb
Ambient temperature too high or too low
protection
5 Ed Anti-freezing reminder
No. Display Failure Description
1 E1 High pressure protection
2 E2 Low pressure protection
3 E4
3 phase sequence protection
(three phase only)
4 E7
Water outlet temp too high or too low
protection
5 E8 High exhaust temp protection
6 EA
Evaporator overheat protection
(only at cooling mode)
7 P0 Controller communication failure
8 P1 Water inlet temp sensor failure
9 P2 Water outlet temp sensor failure
10 P3 Gas exhaust temp sensor failure
11 P4 Evaporator coil pipe temp sensor failure
12 P5 Gas return temp sensor failure
13 P6 Cooling coil pipe temp sensor failure
14 P7 Ambient temp sensor failure
15 P8 Cooling plate sensor failure
16 P9 Current sensor failure
17 PA Restart memory failure
18 F1 Compressor drive module failure
19 F2 PFC module failure
20 F3 Compressor start failure
21 F4 Compressor running failure
22 F5 Inverter board over current protection
23 F6 Inverter board overheat protection
24 F7 Current protection
25 F8 Cooling plate overheat protection
26 F9 Fan motor failure
27 Fb Power lter plate no-power protection
28 FA PFC module over current protection
Table I. Fault Codes - Inverter Models Only