- 124 -
MULTI TYPE
2, 3, 4 ROOMS TYPE
11. Safety devices
*: Printed Circuit Board
Indoor unit
type
Model name PCB* fuse
Fan motor thermal
protector
Terminal thermal
fuse
Float
switch
Compact
cassette
RICH7AVFJ
RICH9AVFJ
RICH12AVFJ
RICH18AVFJ
250 V, 3.15 A
Activate: 212 ± 27 °F
(100 ± 15 °C)
Fan motor stop
Reset: 203 ± 18 °F
(95 ± 10 °C)
Fan motor restart
ʊż
Slim duct
RIDH7AVFJ
RIDH9AVFJ
RIDH12AVFJ
RIDH18AVFJ
RIDH24AVFJ
250 V, 3.15 A
Activate: 275 ± 27 °F
(135 ± 15 °C)
Fan motor stop
Reset: 239 ± 27 °F
(115 ± 15 °C)
Fan motor restart
ʊż
Wall mounted
RIWH7AVFJ
RIWH9AVFJ
RIWH12AVFJ
RIWH15AVFJ
250 V, 3.15 A
Activate: 221 ± 18 °F
(105 ± 10 °C)
Fan motor stop
Reset: 194 ± 18 °F
(90 ± 10 °C)
Fan motor restart
ʊʊ
ʊ
RIWH18AVFJ
RIWH24AVFJ
250 V, 3.15 A
Activate: 302 ± 27 °F
(150 ± 15 °C)
Fan motor stop
Reset: 248 ± 27 °F
(120 ± 15 °C)
Fan motor restart
Activate: 216 °F
(102 °C)
ʊ
Floor
RIFH9AVFJ
RIFH12AVFJ
RIFH15AVFJ
250 V, 3.15 A
Activate: 302 ± 27 °F
(150 ± 15 °C)
Fan motor stop Reset:
248 ± 27 °F (120 ± 15°C)
Fan motor restart
Activate: 216 °F
(102 °C)

Table of Contents