EasyManua.ls Logo

Rheem RIDH09AVFJ - Safety Devices

Rheem RIDH09AVFJ
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 210 -
OUTDOOR UNIT
ROMH18AFXZJ
12. Safety devices
*Pressure switch 2: For control device. (Refer to the wiring diagram.)
Type of protection Protection form
Model
ROMH18AFXZJ
Circuit protection
Current fuse
(Main PCB)
250 V, 5 A
250 V, 3.15 A
Current fuse
(Near the terminal)
250 V, 10 A
Fan motor protection Temperature thermistor
Activate
302 ±27 °F
(150 ±15 °C)
Fan motor stop
Reset
248 ±27 °F
(120 ±15 °C)
Fan motor restart
Compressor protection Temperature thermistor
Activate
230 ±4 °F
(110 ±2 °C)
Compressor stop
Reset
176 ±4 °F
(80 ±2 °C)
Compressor restart
Refrigerant circuit
protection
Pressure switch 1
Activate
609 ±15 PSI
(4.2 ±0.1 MPa)
Reset
464 ±22 PSI
(3.2 ±0.15 MPa)

Table of Contents