EasyManua.ls Logo

Rheem ROMH45AFXZJ - Page 113

Rheem ROMH45AFXZJ
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Indoor unit connect-
ing capacity
Outdoor temperature
Indoor temperature
60 °FDB 65 °FDB 70 °FDB 75 °FDB 78 °FDB
kBtu/h °FDB °FWB TC IP TC IP TC IP TC IP TC IP
38
5
3 28.0 3.93 27.3 4.01 26.6 4.10 26.0 4.18 25.3 4.26
14 12 31.5 3.93 30.8 4.01 30.0 4.10 29.3 4.18 28.5 4.26
23 19 35.1 3.93 34.3 4.01 33.4 4.10 32.6 4.18 31.8 4.26
32 28 40.9 3.93 39.9 4.01 38.9 4.10 38.0 4.18 37.0 4.26
41 37 46.7 3.93 45.6 4.01 44.5 4.10 43.4 4.18 42.2 4.26
47 43 47.9 3.54 46.7 3.61 45.6 3.69 44.5 3.76 43.3 3.84
50 47 47.9 3.54 46.7 3.61 45.6 3.69 44.5 3.76 43.3 3.84
59 50 47.9 3.30 46.7 3.37 45.6 3.44 44.5 3.50 43.3 3.57
68 59 45.7 2.86 44.6 2.92 43.5 2.97 42.4 3.03 41.3 3.09
75 65 43.6 2.61 42.5 2.66 41.5 2.72 40.4 2.77 39.4 2.83
37
5
3 27.2 3.83 26.6 3.91 25.9 3.99 25.3 4.07 24.6 4.15
14 12 30.7 3.83 30.0 3.91 29.2 3.99 28.5 4.07 27.8 4.15
23 19 34.2 3.83 33.4 3.91 32.6 3.99 31.7 4.07 30.9 4.15
32 28 39.8 3.83 38.9 3.91 37.9 3.99 37.0 4.07 36.0 4.15
41 37 45.5 3.83 44.4 3.91 43.3 3.99 42.2 4.07 41.1 4.15
47 43 46.6 3.44 45.5 3.51 44.4 3.58 43.3 3.66 42.2 3.73
50 47 46.6 3.44 45.5 3.51 44.4 3.58 43.3 3.66 42.2 3.73
59 50 46.6 3.21 45.5 3.27 44.4 3.34 43.3 3.41 42.2 3.47
68 59 44.5 2.78 43.4 2.83 42.4 2.89 41.3 2.95 40.3 3.01
75 65 42.4 2.54 41.4 2.59 40.4 2.64 39.4 2.70 38.4 2.75
36
5
3 26.5 3.72 25.9 3.79 25.2 3.87 24.6 3.95 24.0 4.02
14 12 29.9 3.72 29.2 3.79 28.5 3.87 27.7 3.95 27.0 4.02
23 19 33.3 3.72 32.5 3.79 31.7 3.87 30.9 3.95 30.1 4.02
32 28 38.7 3.72 37.8 3.79 36.9 3.87 36.0 3.95 35.1 4.02
41 37 44.2 3.72 43.2 3.79 42.1 3.87 41.1 3.95 40.0 4.02
47 43 45.4 3.34 44.3 3.41 43.2 3.48 42.1 3.55 41.0 3.62
50 47 45.4 3.34 44.3 3.41 43.2 3.48 42.1 3.55 41.0 3.62
59 50 45.4 3.11 44.3 3.18 43.2 3.24 42.1 3.31 41.0 3.37
68 59 43.3 2.70 42.3 2.75 41.2 2.81 40.2 2.86 39.2 2.92
75 65 41.3 2.46 40.3 2.52 39.3 2.57 38.3 2.62 37.3 2.67
35
5
3 25.8 3.60 25.1 3.68 24.5 3.75 23.9 3.83 23.3 3.90
14 12 29.0 3.60 28.4 3.68 27.7 3.75 27.0 3.83 26.3 3.90
23 19 32.3 3.60 31.6 3.68 30.8 3.75 30.0 3.83 29.3 3.90
32 28 37.7 3.60 36.8 3.68 35.9 3.75 35.0 3.83 34.1 3.90
41 37 43.0 3.60 42.0 3.68 41.0 3.75 39.9 3.83 38.9 3.90
47 43 44.1 3.24 43.1 3.31 42.0 3.38 41.0 3.44 39.9 3.51
50 47 44.1 3.24 43.1 3.31 42.0 3.38 41.0 3.44 39.9 3.51
59 50 44.1 3.02 43.1 3.08 42.0 3.15 41.0 3.21 39.9 3.27
68 59 42.1 2.62 41.1 2.67 40.1 2.72 39.1 2.78 38.1 2.83
75 65 40.1 2.39 39.2 2.44 38.2 2.49 37.3 2.54 36.3 2.59
34
5
3 25.0 3.49 24.4 3.57 23.8 3.64 23.2 3.71 22.6 3.79
14 12 28.2 3.49 27.5 3.57 26.9 3.64 26.2 3.71 25.5 3.79
23 19 31.4 3.49 30.7 3.57 29.9 3.64 29.2 3.71 28.4 3.79
32 28 36.6 3.49 35.7 3.57 34.8 3.64 34.0 3.71 33.1 3.79
41 37 41.8 3.49 40.8 3.57 39.8 3.64 38.8 3.71 37.8 3.79
47 43 42.8 3.15 41.8 3.21 40.8 3.28 39.8 3.34 38.8 3.41
50 47 42.8 3.15 41.8 3.21 40.8 3.28 39.8 3.34 38.8 3.41
59 50 42.8 2.93 41.8 2.99 40.8 3.05 39.8 3.11 38.8 3.17
68 59 40.9 2.54 39.9 2.59 38.9 2.64 38.0 2.70 37.0 2.75
75 65 39.0 2.32 38.0 2.37 37.1 2.42 36.2 2.46 35.3 2.51
NOTE:
Specifications are based on the following conditions.
Power source of specifications: 230 V
2 or more indoor units should be connected.
Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit - Indoor
unit]
The total ability of connected a indoor unit is from 34,000 Btu up to 54,000 Btu.
Input in the table are calculated based on the maximum indoor unit input combi-
nations.
- 107 -
OUTDOOR UNIT
ROMH45AFXZJ

Table of Contents

Related product manuals