EasyManua.ls Logo

Rheem ROMH45AFXZJ - Page 119

Rheem ROMH45AFXZJ
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Heating capacity in kW
TC: Total Capacity (kW).
The data is based on the following conditions:
Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit - Indoor unit]
MODEL: RIWH07AVFJ
Outdoor temperature
Indoor temperature (°CDB)
15.6 18.3 21.1 23.9 25.6
(°CDB) (°CWB) TC TC TC TC TC
-15.0 -16.1 1.51 1.47 1.44 1.40 1.37
-10.0 -11.1 1.70 1.66 1.62 1.58 1.54
-5.0 -7.2 1.90 1.85 1.80 1.76 1.71
0.0 -2.2 2.21 2.16 2.10 2.05 2.00
5.0 2.8 2.52 2.46 2.40 2.34 2.28
8.3 6.1 2.58 2.52 2.46 2.40 2.34
10.0 8.3 2.58 2.52 2.46 2.40 2.34
15.0 10.0 2.58 2.52 2.46 2.40 2.34
20.0 15.0 2.47 2.41 2.35 2.29 2.23
23.9 18.3 2.35 2.30 2.24 2.18 2.13
MODEL: RIWH09AVFJ
Outdoor temperature
Indoor temperature (°CDB)
15.6 18.3 21.1 23.9 25.6
(°CDB) (°CWB) TC TC TC TC TC
-15.0 -16.1 1.94 1.90 1.85 1.80 1.76
-10.0 -11.1 2.19 2.14 2.08 2.03 1.98
-5.0 -7.2 2.44 2.38 2.32 2.26 2.20
0.0 -2.2 2.84 2.77 2.70 2.64 2.57
5.0 2.8 3.24 3.16 3.09 3.01 2.93
8.3 6.1 3.32 3.24 3.17 3.09 3.01
10.0 8.3 3.32 3.24 3.17 3.09 3.01
15.0 10.0 3.32 3.24 3.17 3.09 3.01
20.0 15.0 3.17 3.10 3.02 2.95 2.87
23.9 18.3 3.02 2.95 2.88 2.81 2.74
MODEL: RIWH12AVFJ
Outdoor temperature
Indoor temperature (°CDB)
15.6 18.3 21.1 23.9 25.6
(°CDB) (°CWB) TC TC TC TC TC
-15.0 -16.1 2.59 2.53 2.47 2.40 2.34
-10.0 -11.1 2.92 2.85 2.78 2.71 2.64
-5.0 -7.2 3.25 3.17 3.09 3.02 2.94
0.0 -2.2 3.79 3.69 3.60 3.51 3.42
5.0 2.8 4.32 4.22 4.12 4.01 3.91
8.3 6.1 4.43 4.33 4.22 4.11 4.01
10.0 8.3 4.43 4.33 4.22 4.11 4.01
15.0 10.0 4.43 4.33 4.22 4.11 4.01
20.0 15.0 4.23 4.13 4.03 3.93 3.83
23.9 18.3 4.03 3.94 3.84 3.74 3.65
- 113 -
OUTDOOR UNIT
ROMH45AFXZJ

Table of Contents

Related product manuals