- (01-17) -
WALL MOUNTED TYPE
RIWH09-12AVFJ
WALL MOUNTED TYPE
RIWH09-12AVFJ
ERROR STATUS OUTPUT
An air conditioner error status signal can be output.
z
Circuit diagram example
*: Make the distance from the PC board to the connected unit within 33ft. (10m)
Relay spec.: Max. DC 24 V, 10 mA to less than 500 mA.
z
Parts (Optional)
Parts name
Model name
External connect kit RXXWZXZ5
Communication kit RXXCBXZ2
* For operating the EXTERNAL function, the wall mounted type requires the communication kit in addition to the wire
(RXXWZXZ5).
Wire (External output) : RXXWZXZ5
Ex.)Display
Indoor unit
control PC board Communication kit Connected unit
Ex.)Relay unit
1
2
Signal
Relay
power
supply
V
Connector
*33ft.
(10m)
24V DC
Optional parts Locally purchased
ON
OFF
Error
Normal
Error status
Output signal