DIMENSIONS AND TECHNICAL DATA – XC MODELS
Fitting connections: O = outlet (red), I = inlet (blue)
All dimensions are in mm
Model
XC-10 XC-15 XC-30
Nominal Storage Capacity Litres
10 15 30
Voltage Volts
220-240
220-240
220-240
Frequency Hz 50-60 50-60 50-60
Dimensions
Mounting holes to water connections A mm 290 290 356
Mounting holes to right hand jacket B mm 151 151 193
Spacing between mount holes C mm 61 61 61
Depth D mm 251 318 380
Inlet connection to right hand jacket F mm 129 129 383
Height including fittings G mm 371 371 460
Height H mm 356 356 447
Width W mm 363 363 447
Water connection from wall I/O mm 90 90 120
Thermostat setting (factory setting) °C 70 70 70
Pressure Relief Valve Setting kPa 800 800 800
Maximum inlet water pressure kPa 640 640 640
Water inlet/outlet connections
G 1/2 B G 1/2 B G 1/2 B
Approx. Weight empty kg 8 9 14
Approx. Weight full kg 18 24 44
All models are suitable for indoor installation only, ingress protection = IP24.