The assembly and installation must be carried out in accordance with the national
regulations of the country of use.
The stove should be installed away from all flammable materials and at least 5 cm away
from walls.
The installation location must have sufficient space and ventilation.
The assembly and installation must, in all cases, comply with the safety requirements in
force.
Remove all protective film and stickers before use.
Refer Figure 1 for the illustrartion of an assembled stove.
4.3- Connecting to gas supply
Preparation
Use suitable hose that meets below standards:
Hose type
Standard
Flexible hose with clamp
XP D 36-110
Reinforced rubber hose
XP D 36-112
Metal hose
NF EN 14800 + NF D 36-125
The hose must not exceed 1.5 metres.
Ensure the hose is free from stress, torsion, traction or bend.
The regulator and safety valve must comply with the standards in force in the country of
marketing.
Use with suitable gas supply only: either butane (G30) or propane (G31).
Connection
Ensure the appliance control knob is set to the OFF position.
Ensure gas regulator valve or the safety valve is set to the OFF position.
Attach the appliance to gas supply with the flexible hose appropriately.
Ensure the gas pressure is 28-30 mbar for butane gas, or 37 mbar for propane.
After each connection, perform leakage test in well ventilated area and away from heat
source.
Leakage test
Ensure the location is well ventilated and away from heat source.
Prepare soapy water by mixing equal portion of water and non-ammonia detergent.
Turn ON the gas safety valve.
Transfer few drops of soapy water to the connections.
If bubble forms, leakage are found, then turn OFF the gas safety valve and tighten the
connection. Repeat the test until no bubble is formed, or call for professional service.
4.4- Turn ON and OFF
Ignition
Turn ON the gas safety valve.
Push the control knob, then turn anticlockwise until a click is heard and the burner is lit.
If it is not light, turn the knob to the OFF position and repeat the ignition process.
Power adjustment
Turn the control knob to appropriate position for the power adjustment.
Turn OFF