USING SERVICE PROGRAM MODE
SM 5-17 B044/B045/B046
Service
Tables
5
Mode Number/Name Function/[Setting]
PCU Alarm
1 Alarm Display On/Off Selects whether or not the machine will display a "Replace
PCU' warning when the PCU alarm counter reaches the
interval set by SP912-2.
[0 = Display / 1 = Do not display]
912*
2 Interval Sets the PCU Alarm interval (count) at which a "Replace
PCU' warning occurs.
[1 ~ 255 / 45 / 1000 sheets/step]
UP Mode Data Reset913
1 Resets the user tools settings (with the exception of the
copy user codes and copy user code counters).
[0 = No / 1 = Yes]
• This operation is equivalent to executing a System
Reset with the User Tools.
• After selecting “1”, hold down the Original Type key and
press the OK key (or ' key) to execute the reset. If the
reset is successful, the display shows “Action
completed.” If the reset fails, the display shows “Error!!!”
Preset Small-Size Setting956
1 Enables setting of small paper sizes.
[0 = No / 1 = Yes]
• Setting this value to "1" enables setting of the following
standard small sizes, for both paper tray and bypass
tray: B5 SEF, Executive SEF.
If you change the setting from "1" to "0" when one of
these sizes is set, the size setting changes to each
tray's default.
Debug Monitor Mode991*
1
[0 ~ 3 / 0 / 1/step] DFU
SMC Printing992
Prints out machine data. (
☛
5.1.5)
[0 = No / 1 = SP settings / 2 = All / 3 = Memory]