COPY IMAGE ADJUSTMENTS: PRINTING/SCANNING
SM 3-37 B044/B045/B046
Replacement
and
Adjustment
3.13.3 DF IMAGE ADJUSTMENT
Registration and Blank Margin
NOTE: Make a temporary test chart as shown above, using A4 / 8
1/2
"x11" paper.
1. Place the temporary test chart on the DF and make a copy from one of the feed
stations.
2. Check the registrations, and adjust as necessary using SP mode, as follows.
SP mode
Side-to-side registration SP6-006-1
Leading edge registration SP6-006-2
Blank margin for the t
railing edge SP6-006-3
Sub-scan Magnification
NOTE: Make a temporary test chart as shown above, using A4 / 8
1/2
"x11" paper.
1. Place the temporary test chart on the DF and make a copy from one of the feed
stations.
2. Check the registration, and if necessary adjust it using SP6-007. The
specification is ±1.0%.
A
B
B046R559.WMF
B046R556.WMF
A
B046R558.WMF
A: Sub-scan magnification
A: Leading edge registration
B: Side-to-side registration