9 March 2004 DOCUMENT FEEDER
1-23
Installation
9. Remove the left scale plate [A]
(
"
x 2).
10. Remove the upper left cover [B].
11. Set the ADF body [C] onto the
copier.
12. Press the latch [D] to raise the
top half of the body.
13. Fasten the ADF body with the
hex screws (" x 4).
NOTE: Use the hex wrench.
B696I904.WMF
B696I903.WMF
[A]
[D]
[C]
[B]