SP5xxx: Mode
D017/D018/D019/D020 5-96 SM
2: Network remote diagnostics.
CE Call
2
Lets the customer engineer start or end the remote machine check with CSS
or NRS; to do this, push the center report key
Function Flag
3
Enables and disables remote diagnosis over the NRS network.
[0 to 1/1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
SSL Disable
7
Controls if RCG (Remote Communication Gate) confirmation is done by SSL
during an RCG send for the NRS over a network interface.
[0 to 1/1]
0: Yes. SSL not used.
1: No. SSL used.
RCG Connect Timeout
8
Sets the length of time (seconds) for the time-out when the RCG (Remote
Communication Gate) connects during a call via the NRS network.
[1 to 90/1 sec.]
RCG Write Timeout
9
Sets the length of time (seconds) for the time-out when sent data is written
to the RCG during a call over the NRS network.
[0 to 100/1 sec.]
RCG Read Timeout
10
Sets the length of time (seconds) for the timeout when sent data is written
from the RCG during a call over the NRS network.
[0 to 100/1 sec.]
11 Port 80 Enable