012 Interval:Disp:FC *ENG
Displays the page interval for job end process
control.
[0 to 5000 / - / 1sheets/step]
013 Corr(Short):FC *ENG
Sets the correctin coeficient (Short) for job end
process control.
[0.00 to 1.00 / 0.50 / 0.01/step]
014 Corr(Mid):FC *ENG
Sets the correctin coeficient (Mid) for job end
process control.
[0.00 to 1.00 / 1 / 0.01/step]
3539 [Dev Agitating Time :Set]
001 Time *ENG
Sets the developer agitating time.
[0 to 5000 / 10 / 1sec/step]
010 ON/OFF(by AbsHum) *ENG
Sets on/off for relative humidity correction of
the developer agitating time.
[0 or 1 / 1 / 1/step]
0:OFF, 1:ON
011 AbsHum:1 *ENG [0 to 3000 / 0 / 1sec/step]
012 AbsHum:2 *ENG [0 to 3000 / 0 / 1sec/step]
013 AbsHum:3 *ENG [0 to 3000 / 5 / 1sec/step]
014 AbsHum:4 *ENG [0 to 3000 / 5 / 1sec/step]
015 AbsHum:5 *ENG [0 to 3000 / 5 / 1sec/step]
016 AbsHum:6 *ENG [0 to 3000 / 5 / 1sec/step]
021 AbsHum Threshold:1 *ENG [0.0 to 65.0 / 4.0 / 0.1g/m3/step]
022 AbsHum Threshold:2 *ENG [0.0 to 65.0 / 8.0 / 0.1g/m3/step]
023 AbsHum Threshold:3 *ENG [0.0 to 65.0 / 12.0 / 0.1g/m3/step]
024 AbsHum Threshold:4 *ENG [0.0 to 65.0 / 16.0 / 0.1g/m3/step]
025 AbsHum Threshold:5 *ENG [0.0 to 65.0 / 24.0 / 0.1g/m3/step]
Main SP Tables-3
205