3550 [Refresh Mode]
001 Required Area: K *ENG
Displays the image area requiring the reflesh.
[0 to 65535 / - / 1cm^2/step]
002 Required Area: C *ENG
003 Required Area: M *ENG
004 Required Area: Y *ENG
011
Dev. Motor Rotation:
Display: Bk
*ENG
Displays the developer motor rotation between
the reflesh mode executions.
[0.0 to 1000.0 / - / 0.1m/step]
012
Dev. Motor Rotation:
Display: C
*ENG
013
Dev. Motor Rotation:
Display: M
*ENG
014
Dev. Motor Rotation:
Display: Y
*ENG
021 Rotation Threshold *ENG
Sets the threshold of reflesh mode execution
determination.
[0.0 to 1000.0 / 0.1 / 0.1m/step]
031 Reflesh Threshold: Bk *ENG
Sets the reflesh execution threshold at toner
density adjustment.
[0 to 255 / 25 / 1cm^2/m/step]
032 Reflesh Threshold: C *ENG
Sets the reflesh execution threshold at toner
density adjustment.
[0 to 255 / 25 / 1cm^2/m/step]
033 Reflesh Threshold: M *ENG
034 Reflesh Threshold: Y *ENG
041 Job End Area Coefficient *ENG [0.0 to 25.5 / 1.0 / 0.1/step]
042 Job End Vb Coefficient *ENG [0 to 100 / 30 / 1%/step]
043 Job End Length *ENG [0 to 99 / 77 / 1mm/step]
044 Job End Supply *ENG
[0.000 to 1.000 / 0.450 / 0.001mg/cm2/
step]
3. SP Mode Tables