Main SP Tables-2
SM 5-123 D086/D087
System
Maintenance
2920 [Transfer Motor Control]
001
0: Encorder 1 :FG *ENG
[0 or 1 / 0 / 1 /step]
Selects the speed control mode for the ITB.
If SC443 occurs and machine does not recover, change this setting to "1".
002
SC443 Count *ENG
[0 to 3 / 0 / 1 /step]
Displays the number of the ITB encodre error. SC443 is displayed if this
counter counts to "3".
2930
[SecondaryFB: Threshold] Paper Transfer Roller Feed-back: Threshold
Adjustment
Adjusts the threshold between high resistance (division 1) and low resistance
(division 2) at the paper transfer roller. This SP affects SP2931 to SP2939.
001 Voltage *ENG
[0 to 7000 / 6000 / 10 –V/step]
2960 [Process Interval]
001
Additional Time *ENG
[0 to 10 / 0 / 1 sec/step]
Adjusts the additional time for ending the machine's process.
2970 [Cleaning After JOB]
001
No Refresh *ENG
[0 to 100 / 50 / 1 /step]
0: No cleaning
Specifies the threshold sheets for the cleaning of the paper transfer roller
without the refresh mode.
002 Refresh *ENG
[0 or 1 / 1 / 1 /step]
0: No cleaning, 1: Cleaning