Main SP Tables-3
D086/D087 5-134 SM
3044
[Toner Supply Type] Toner Supply Type ([Color])
Selects the toner supply method type.
001 Bk *ENG
[0 to 3 / 2 / 1/step] Alphanumeric
0: FIXED (with the supply rates stored with
SP 3401)
1: PID (Vtref_Fixed)
2: PID (Vtref_Control)
3: Not used
002 M *ENG
003 C *ENG
004 Y *ENG
3045
[Toner End Detection: Set]
Enables/disables the toner alert display on the LCD.
001 ON/OFF *ENG
[0 or 1 / 0 / 1/step] 0: Detect, 1: Not Detect
3102
[Toner End Recovery]
Adjusts the number of times toner supply is attempted for each color when the
TD sensor continues to detect toner end during toner recovery.
001 Repeat: Bk *ENG
[1 to 20 / 5 / 1 time/step]
002 Repeat: M *ENG
003 Repeat: C *ENG
004 Repeat: Y *ENG
3131
[TE Count m: Display]
Display the number of toner end detections for each color.
001 Bk *ENG
[0 to 99 / 0 / 1 time/step]
002 M *ENG
003 C *ENG
004 Y *ENG