SC No. Level Error Name/Error Condition/Major Cause/Solution
SC544-00 A
Fusing (Center) thermopile high-temperature detected (hardware)
The hardware high-temperature error Sensor flag is detected.
Damaged triac (shorted)
Failed engine control board
Failed fusing thermopile
Failed fusing thermistor
Abnormal fusing control software behavior
The PWM signal is continuously supplied from the IH inverter (due to
a software or temperature Sensor error).
Clear the SP: fusing SC.
Replace the PSU.
Replace the Engine Board.
Replace the fusing thermopile.
Replace the Fusing Unit.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC545-00 A
Fusing (Center) heater stay ON
The thermistor (center) has not detected the target temperature, even after
the fusing heater stays ON for more than 30 seconds after reloading.
Deformed or floating thermistor
Broken fusing lamp wire
The overtemperature prevention mechanism started working
Clear the SP: fusing SC.
Replace the fusing thermistor.
Replace the fusing (Center) lamp.
Service Call