SC No. Level Error Name/Error Condition/Major Cause/Solution
SC547-01 D
Zero-crossing error (adhered relay contact)
When the fusing relay is in an OFF state, a "zero-crossing interrupt
request" occurs in 50 ms.
Damaged fusing relay (adhered contact)
Turn the main power OFF and then ON.
Replace the harness.
Replace the PC board.
Replace the PSU.
SC547-02 D
Zero-crossing error (bad relay contact)
If a "zero-crossing interrupt request" does not occur when the fusing relay
is in an ON state, an error results.
Damaged fusing relay (open contact)
Failed fusing relay drive circuit
PSU fuse (24VS) blown
Turn the main power OFF and then ON.
Replace the harness.
Replace the Engine Board.
Replace the PSU.
Replace the fuse.
SC547-03 D
Zero-crossing error (low frequency error)
The number of zero-crossing interrupts does not reach a certain value in
500 ms.
The frequency of the commercial power supply line is unstable.
Turn the main power OFF and then ON.
Check the commercial power supply line.
Replace the harness.
Replace the Engine Board.
Replace the PSU.
6. Troubleshooting