SC No. Level Error Name/Error Condition/Major Cause/Solution
SC670-00 D
Engine start up error
The /ENGRDY signal is not detected even after the specified time
has elapsed after turning the main power on or restoring from
energy saver mode.
The /ENGRDY signal is detected, but it is negated at an unexpected
occasion*.
* Expected negation occurs when turning the power off, switching
to the energy saver mode (after the engine automatically goes off),
and rebooting the machine.
The engine board does not start up.
The connection between the controller board and engine board is
faulty.
Check the connection between the engine board and the controller
board.
If this problem always occurs, replace the engine board. If the
problem persists, consider replacing the controller board or other
boards between them.
If this problem occasionally occurs, multiple causes are to be
considered, such as the software, engine board, controller board,
and PSU.