1-105-001 C: Plain1 E [140 to 205 / 167 / 1deg/step]
1-105-003 C: Plain2 E [140 to 205 / 174 / 1deg/step]
1-105-005 C: Thick1 E [140 to 205 / 180 / 1deg/step]
1-105-007 C: Thick2 E [140 to 205 / 190 / 1deg/step]
1-105-011 C: Thin E [140 to 205 / 160 / 1deg/step]
1-105-013 C: Envelope E [140 to 205 / 205 / 1deg/step]
1-105-015 C: Card E [140 to 205 / 190 / 1deg/step]
1-105-017 C: Transparency E [140 to 205 / 165 / 1deg/step]
1-105-019 C: Special E [140 to 205 / 180 / 1deg/step]
1-105-023 C:Middle Thick E [140 to 205 / 177 / 1deg/step]
1-105-025 C:Thick1(LowTemp) E [140 to 205 / 185 / 1deg/step]
1-105-031 FuserOffMode E
[0 or 1 / 1 / 1/step]
The switch that turns the fuser off after the idle
process runs over 30 minutes.
1105 [Curl Dec Mode]
1-105-021 Mode Display E
[0 or 1 / 0 / 1 /step]
Enables or disables the CurlDecMode (0:
Disabled, 1: Enabled)
1-105-022 PreprtRotTime E
[500 to 60000 / 20000 / 500msec/step]
Sets the pre-print rotation time for reducing
curls.
1106
[Fusing Temp Disp]
This SP displays the hot roller and pressure roller temperatures.
1-106-001 RollerCenter E
[-20 to 250 / 0 / 1deg/step]
Displays the current fusing thermistor
temperature (Center).
3. Appendices: SP Mode Tables