2-001-100 F:Coefficient:a0 E
[-500 to -350 / -350 / 1/step]
Displays and adjusts the coefficient a0 used
for the C-caluculated function F (Vd, AH, D).
This setting is available when the bias
control is On.
2-001-101 F:Coefficient:a1 E
[0.80 to 1.20 / 1.00 / 0.01/step]
Displays and adjusts the coefficient a1 used
for the C-caluculated function F (Vd, AH, D).
This setting is available when the bias
control is On.
2-001-102 F:Coefficient:a2 E
[0.0 to 10.0 / 5.0 / 0.1/step]
Displays and adjusts the coefficient a2 that is
of the C-caluculated function F (Vd, AH, D).
This setting is available when the bias
control is On.
2-001-103 F:Coefficient:a3 E
[-20 to 0 / -9.9 / 0.1/step]
Displays and adjusts the coefficient a3 that is
of the C-caluculated function F (Vd, AH, D).
This setting is available when the bias
control is On.
2101
[Reg Correct]
The amount of the correction for the main scan position.
2-101-001 Main Dot E [-300 to 300 / 0 / 1dot/step]
2102
[Magnification Adj]
Sub Scan Magnification Adjustment
2-102-002 Sub Mag.:N E [-1.0 to 1.0 / 0.0 / 0.1%/step]