2-926-003 Recovery Count E
[0 to 10000 / 0 / 1count/step]
Total count of executed Recovery Supply
2-926-004 Self-Recovery E
[- / - / -]
[Execute]
Forcibly executes one time Recovery Supply.
2927 [Initial Supply]
2-927-001 Initial Amount E
[1 to 50 / 10 / 1g/step]
Target toner amount for supplying fixed
amount of toner when replacing.
2-927-002 Initial Mixing T E
[0 to 300 / 10 / 1sec/step]
Idle time to mix for supplying fixed amount of
toner when replacing.
2-927-003 Ini-Coefficient E
[0.0 to 5.0 / 1.5 / 0.1/step]
Coefficient for calcurating the amount of
toner supplying during printing after toner
cartridge is replaced.
2-927-004 Initial Flag E
[0 or 1 / 0 / 1/step]
Information used to detect the replacements
and judge the upper limit.
2-927-005 Exchange Count E
[0 to 1000 / 0 / 1count/step]
Counter for new toner detection.
2930 [Detection]
2-930-001 Cleaner Count E
[1 to 20 / 5 / 1cycle/step]
Counter to rotate the cleaner parts when
remaining toner in the developer detected.
2-930-002 stabilization T E
[0.0 to 3.0 / 0.0 / 0.1sec/step]
Stability time of the sensor used for detecting
remaining toner in the developer.