5816 [Remote Service]
5-816-002 CE Call C
[0 or 1 / 0 / 1/step]
0: Start of the service
1: End of the service
Performs the CE Call at the start or end of the
service.
Note: This SP is activated only when
SP5816-001 is set to “1”.
5-816-003 Function Flag C
[0 or 1 / 0 / 1/step]
0: Disabled
1: Enabled
Enables or disables the remote service
function.
NOTE: This SP setting is changed to "1" after
@Remote register has been completed.
5-816-004 Commnication Test C
[- / - / -]
[Execute]
Judges whether or not to communicate with
the center correctly after the NRS equipment
is set.
The communication test call is executed in
remote service.
A return value of the execution is 0 to 99.
0: Normally finished (during the center in
operation)
1: Normally finished (during the center out of
operation)
Other number: Abnormally finished
Communication can not be performed If
SP5-515-006 is disabled.
Main SP Tables-5