EasyManua.ls Logo

Ricoh Aficio MP171 - Page 29

Ricoh Aficio MP171
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Value Meaning Solution/ Workaround
5
Proxy error (Illegal user name or
password)
Check Proxy user name and password.
8 Other error See "SP5816-208 Error Codes" below this.
9
Request number confirmation
executing
Processing… Please wait.
20 Dial-up authentication error
These errors occur only in the modems that
support @Remote.
21 Answer tone detection error
22 Carrier detection error
23 Invalid setting value (modem)
24 Low power supply current
25 unplugged modem
26 Busy line
8. Exit the SP mode.
SP5816-208 Error Codes
Cause Code Meaning Solution/ Workaround
Operation Error,
Incorrect Setting
-1200
3
Attempted registration without
execution of a confirmation and
no previous registration.
Perform Confirmation before
attempting the Registration.
-1200
4
Attempted setting with illegal
entries for certification and ID2.
Check ID2 of the mainframe.
-1200
6
A confirmation request was made
after the confirmation had been
already completed.
Execute registration.
-1200
8
Update certification failed
because mainframe was in use.
Check the mainframe
condition. If the mainframe is
in use, try again later.
Settings for @Remote Service
27

Table of Contents