5. Release the bearing at the right end of the registration roller (drive), and remove the
grounding plate [A] ( x 1, x 1).
6. Insert a flathead screwdriver into the gap on the left of the registration roller guide to
release the protruding part.
7. Release the harness from the guide [A] to detach the guide [A] with the registration roller
(driven).
4. Replacement and Adjustment
90